That beam is called a masonry lintel. It carries the weight of the brick above the window and passes it to the wall on each side. This guide covers what owners, contractors, and designers should check before the first cut, from wall condition and lintel sizing to flashing and patch work.
Cutting a new drive-thru window into a brick wall can take about a day. Living with a poorly supported opening can take years, in the form of cracked mortar, sagging brick, and water stains running down from the corners. The part that decides which way it goes is the beam over the opening.
Evaluating Existing Masonry Walls for New Drive-Thru Openings
Start by finding out what kind of wall you’re cutting into. Many commercial buildings have brick veneer, which is a single layer of brick tied to a wood, steel, or concrete block backup wall. Others have load-bearing brick or block walls that hold up the roof or floors. The wall type changes how the opening gets supported and who needs to design it.
Look closely at the wall’s condition before picking a location. Cracks, loose brick, bulging, and worn mortar near the planned opening can signal movement or water problems that a new cut will make worse. Check what’s inside the wall as well, including electrical lines, plumbing, roof drains, and steel columns.
For load-bearing walls, a structural engineer should review the plan before work begins. The wall will need temporary shoring while the opening is cut and the new lintel is set. Permit requirements vary by local code and project scope, so check with the building department early.
Determining Masonry Lintel Size and Load Support Requirements
A lintel has to carry the masonry above the opening plus any roof, floor, or equipment load bearing on that part of the wall. In many cases, brick above an opening forms a natural arch, so the lintel only carries a triangle of masonry instead of the full wall height. That arching only works when there’s enough solid masonry above and beside the opening. Nearby openings, control joints, or concentrated loads can change the math.
Size depends on the span, the load, the wall type, and how much bending the lintel can handle. Masonry cracks with very little movement, so lintels are designed to limit bending as well as carry weight. A wide drive-thru opening usually needs a deeper or heavier member than a standard storefront window.
Bearing length matters as much as size. Bearing is the part of the lintel resting on the wall at each end of the opening, and code and the engineer set the minimum. Short bearing can crush the brick at the ends and send diagonal cracks up from the window corners.
Selecting Lintel Materials for Commercial Service Window Installations
The right masonry lintel material depends on the wall type, the span, the look you want, and budget. Steel angles are common in brick veneer because they’re thin enough to hide in the mortar line and support a single layer of brick. Precast concrete and reinforced masonry lintels are often used in concrete block walls. Stone lintels appear where the opening is meant to be a visual feature, though their spans may be limited unless steel support is added.
Steel needs protection from rust. Galvanized or properly coated steel lasts longer, and rust building up on a steel lintel can expand enough to crack the brick above it. Ask what coating is specified and how cut ends will be touched up in the field.
Match the finish to the building. On a brick masonry storefront, the lintel can sit behind a soldier course, which is a row of bricks standing on end, to hide the steel and frame the opening. On stone masonry walls, a matching cut stone or cast stone head can tie the new window into the existing facade.
Coordinating Lintel Placement With Drive-Thru Window Dimensions
Drive-thru windows come in set sizes, so confirm the rough opening before the lintel is ordered. Get the manufacturer’s rough opening dimensions, the sill height, and any needs for the counter, air curtain, or transaction drawer. Then plan the opening around those numbers instead of forcing a window into a cut that’s already made.
Brick size helps here. Standard modular brick lays up in a repeating pattern of course heights and lengths, so an opening sized to that pattern avoids thin cut pieces at the sides and head. Shifting the opening an inch or two can make it look like it was always part of the building.
Leave room for movement at the top of the window. The window frame shouldn’t carry wall weight, so a gap with a flexible sealant joint usually sits between the lintel and the window head. Sill height also has to work for drivers reaching out of cars and trucks, which the owner, designer, and window supplier should settle together.
Managing Moisture Protection and Masonry Repairs Around New Openings
Every new opening gives water a new way into the wall. Flashing, a waterproof membrane placed over the lintel, catches water that gets behind the brick and directs it back outside. The flashing should extend past the lintel ends with turned-up end dams, and weep holes in the brick just above it let that water drain out.
Cutting an opening disturbs the brick around it. Expect some units near the sides to crack or loosen, and plan to replace them with brick that matches in size, color, and texture. Mortar should match the existing joints in color and strength, since mortar that’s too hard can damage older brick over time.
Check the surrounding wall again once the window is in. Look for new cracks, open joints, and gaps in the sealant around the frame. Catching small issues in the first season costs far less than repairing water damage inside the building later.
Frequently Asked Questions
Do I need an engineer to add a drive-thru window to a brick wall?
Often you do, especially if the wall is load-bearing or the opening is wide. An engineer can size the lintel, check bearing, and design temporary shoring for the cut. Local building departments may also require stamped drawings before issuing a permit. Ask early so engineering doesn’t hold up your schedule.
Can an existing window opening be widened for a drive-thru?
It can, but the old lintel usually comes out and a longer one goes in. Widening the opening increases the span and the load, so the original lintel may no longer be enough. The wall above needs support while the swap happens. Have a mason and engineer review existing conditions first.
Why do cracks form at the corners of window openings?
Diagonal cracks at window corners often point to lintel problems, such as short bearing, too much bending, or rusting steel. They can also come from foundation movement or missing control joints. A crack’s shape and location help a mason narrow down the cause. Have it checked before patching, since filling the crack won’t fix whatever caused it.